Magnetic Amplifier Demonstration Unit, Model: M – 1 – 1800.


This  is  a  very  versatile  unit  which  can  be  used  for  performing  different  experiments  just  by  means  of  selector  switches.  All  the  control  characteristics  of  basic  transductors  and  Magnetic  amplifier  can  be  studied.  The  following  gives  a  list  of  experiments  that can be  performed  with  this  demo unit  

  • Dimension : 250mm × 350mm × 150mm
  • Weight : 10 Kg Approximately

 
SPECIFICATIONS :
 
INPUT SIGNAL :
  1. Control
SIGNALS :
  1. Maximum 500, mAmp DC through  control  winding  for  series  and parallel mag. Amp. connection.
  2. AC Input  in  the  load  circuit  230 Volt,  6 Amps.
OUTPUT :
  1. Maximum  Power  250,VA   D.C.
  2. Output  Voltage  can  be  varied  upto  200 Volt  D.C.
  3. Load  current  can  be  upto  1, Amps.  D.C.
UTILITY :
  1. To  demonstrated  all  the  control  characteristics  of  the  different basic  magnetic  amplifier  circuits.
EXPERIMENTS THAT CAN  BE  PERFORMED  :
  1.  Study  of  B – H  loop  of  the  core  material  used  on  a  C.R.O.
  2. Magnetization  characteristics  of  the  gate  winding  of  the  saturable  reactor.
  3. Control  characteristics  of  a  series  transductors  unit.
  4. Control  characteristics  of  a  parallel  transductors  unit  non – polarized  control  characteristics.
ACCESSORIES REQUIRED  :
  1. Variable  Power  Supply,  Output  :  0 – 30 Volt  at  1 Amp.
  2. Single  Tube  Rheostat  :  100 ohm. / 1 Amp.
  3. D.C.  Ammeter,  Range  :  0 – 1 Amp.  (Desk type)
  4. Resistive  Load.

 

Note: There may be any change in specification due to continuous R & D without notice.

Click below to view catalouge